Below is a list of all the strings that are sent over the General Control TCP port connection. All commands are in ascii format follow by \r
- meetingStarted: Sent when the meeting manager logs into a meeting in either active or test mode.
- meetingEnded: Sent when the meeting manager presses "Meeting Adjournment" signifying the end of the meeting.
- enableLogin: Sent when the meeting manager presses the "Start Roll Call" button.
- disableLogin: Sent when the meeting manager presses the "End Roll Call" button.
- voteStarted: Sent when a vote is started
- voteEnded: Sent when a vote has ended
- voteClear: Sent after the Live Results timer expires
- timerStarted: Sent when the speaker timer is started
- timerStopped: Sent when the speaker timer is stopped
- #:##: A number representation of the current active timer. A use case for these strings would be for displaying in Control System touch panels or using specific times to trigger actions on the AV system such as playing a chime sound over the speakers to signify the timer is running low or has expired.
- Custom Buttons: The serial string you configured in the custom buttons section of setup.